Myoglobin/CK-MB/Troponin I Combo Rapid Test Cassette

A rapid test for the diagnosis of myocardial infarction (MI) to detect Myoglobin,CK-MB and cardiac Troponin I(cTnI) qualitatively in whole blood,serum or plasma.

Product Detail
SUMMARY
  Myoglobin (MYO), Creatine Kinase MB (CK-MB) and cardiac Troponin I (cTnI) are proteins released into the bloodstream after cardiac injury. Myoglobin is a heme-protein normally found in skeletal and cardiac muscle with a molecular weight of 17.8 kDa. When muscle cells are damaged, Myoglobin is released into the blood rapidly due to its relatively small size. The level of Myoglobin increases measurably above baseline within 2-4 hours post-infarct,peaking at 9- 12 hours, and returning to baseline within 24-36 hours.CK-MB is an enzyme also present in the cardiac muscle, with a molecular weight of 87.0 kDa. Creatine Kinase is a dimeric molecule formed from two subunits designated as “M” and “B”, which combine to form three different isoenzymes, CK-MM, CK-BB and CK-MB. CK-MB is the isoenzyme of Creatine Kinase most involved in the metabolism of cardiac muscle tissue.The release of CK-MB into the blood following an MI can be detected within 3-8 hours after the onset of symptoms. It peaks within 9 to 30 hours, and returns to baseline levels within 48 to 72 hours. Cardiac Troponin I is a protein found in cardiac muscle, with a molecular weight of 22.5 kDa.Troponin I is part of a three subunit complex comprised of Troponin T and Troponin C. Along with tropomyosin, this structural complex forms the main component that regulates the calcium sensitive ATPase activity of actomyosin in striated skeletal and cardiac muscle. After cardiac injury occurs, Troponin I is released into the blood 4-6 hours after the onset of pain. The release pattern of Troponin I is similar to CK-MB, but while CK-MB levels return to normal after 72 hours, Troponin I remains elevated for 6-10 days, thus providing for a longer window of detection for cardiac injury. The Myoglobin/CK-MB/Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/Plasma) is a simple test that utilizes a combination of antibody coated particles and capture reagents to qualitatively detect Myoglobin, CK-MB and cardiac Troponin I(cTnI) in whole blood, serum or plasma. The minimum detection level is 50 ng/mL Myoglobin, 5 ng/mL CK-MB and 0.5 ng/mL Troponin I.

PRINCIPLE

  The Myoglobin/CK-MB/Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/Plasma) is a qualitative, membrane based immunoassay for the detection of Myoglobin, CK-MB and cardiac Troponin I(cTnI) in whole blood, serum or plasma. The membrane is pre-coated with specific capture antibodies in each of the test line regions of the test. During testing, the whole blood, serum or plasma specimen reacts with the particle coated with specific antibodies. The mixture migrates upward on the membrane chromatographically by capillary action to react with specific capture reagents on the membrane and generate a colored line. The presence of this colored line in the specific test line region indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.


STORAGE AND STABILITY

  The kit can be stored at room temperature or refrigerated (2-30°C). The test cassette is stable through the expiration date printed on the sealed pouch. The test cassette must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date

工厂声明.png

Find what you need
As a professional IVD manufacturer, MOQ - Rapid Test: 1000 units; PCR: Negotiable.
Related products
INFORMATION
Legal Notice
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Hysen Inc.(USA)
Tel:+1 740 54 76440 Email:support@hysenbio.com www.hysenbio.com
201 E Fifth Street, Suite 1900, Cincinnati, OH 45202, USA
© Copyright - 2020-2024 : All Rights Reserved.
footer footer footer footer
footer +65 8283 1156
footer
privacy settings Privacy settings
Manage Cookie Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.